Install snmp hp proliant




















If you are doing this through ilo, nothing new, we were doing this already. After enabling the SMA service should i configure some snmp polling service to get hardware health. We use WMI to poll our Windows servers.

How can we use that with AMS? SNMP is only snmpv2 in windows which is unencrypted. More than , members are here to solve problems, share technology and best practices, and directly contribute to our product development process.

Sign In. Product Forums More. You're more likely to get an "answered" tag if you just post the solution here. Also, if this ground is already covered, it's entirely reasonable to vote to close this question as a duplicate. The Overflow Blog. Stack Gives Back Safety in numbers: crowdsourcing data on nefarious IP addresses.

Featured on Meta. New post summary designs on greatest hits now, everywhere else eventually. Linked 1. Related 1. Hot Network Questions. Temperature [ ] [ Component ]. The temperature of the component. Thermal Status. The thermal status. What security features does PRTG include?

What can I do? Sensor Settings Overview. For more information about sensor settings, see the following sections:. Since , we offer monitoring solutions for businesses across all industries and all sizes, from SMB to large enterprises. We believe monitoring plays a vital part in reducing humankind's consumption of resources. Our products help our customers optimize their IT, OT and IoT infrastructures, and reduce their energy consumption or emissions — for our future and our environment.

Customer Login. Search Search. Previous Next. Setting Description Sensor Name Enter a meaningful name to identify the sensor. Parent Tags Shows tags that the sensor inherits from its parent device , parent group , and parent probe. Tags Enter one or more tags. The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor: snmphpesystemhealthsensor systemhealth snmphpe hpe Priority Select a priority for the sensor.

Setting Description Primary Channel Select a channel from the list to define it as the primary channel. Graph Type Define how different channels are shown for this sensor: Show channels independently default : Show a graph for each channel.

Stack channels on top of each other : Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic. You cannot use this option in combination with manual Vertical Axis Scaling available in the channel settings.

Stack Unit This setting is only visible if you enable Stack channels on top of each other as Graph Type. Setting Description Scanning Interval Select a scanning interval from the dropdown list. Choose from: 30 seconds 60 seconds 5 minutes 10 minutes 15 minutes 30 minutes 1 hour 4 hours 6 hours 12 hours 24 hours You can change the available intervals in the system administration of PRTG Network Monitor.

If a Sensor Query Fails Select the number of scanning intervals that the sensor has time to reach and to check a device again if a sensor query fails. Choose from: Set sensor to down immediately : Set the sensor to the Down status immediately after the first request fails.

Set sensor to warning for 1 interval, then set to down recommended : Set the sensor to the Warning status after the first request fails. If the second request also fails, the sensor shows the Down status. Set sensor to warning for 2 intervals, then set to down : Set the sensor to the Down status only after the third request fails.

Set sensor to warning for 3 intervals, then set to down : Set the sensor to the Down status only after the fourth request fails. Set sensor to warning for 4 intervals, then set to down : Set the sensor to the Down status only after the fifth request fails.

Set sensor to warning for 5 intervals, then set to down : Set the sensor to the Down status only after the sixth request fails. Setting Description Schedule Select a schedule from the list. Maintenance Window Select if you want to set up a one-time maintenance window.

Choose between: Do not set up a one-time maintenance window : Do not set up a one-time maintenance window. Monitoring is always active. Set up a one-time maintenance window : Set up a one-time maintenance window and pause monitoring. You can define a time span for the pause below. Maintenance Begins This setting is only visible if you enable Set up a one-time maintenance window above.

Maintenance Ends This setting is only visible if you enable Set up a one-time maintenance window above. Dependency Type Select a dependency type.

You can choose from: Use parent : Use the dependency type of the parent object. Select a sensor : Use the dependency type of the parent object. Additionally, pause the current object if a specific sensor is in the Down status or in the Paused status because of another dependency. Master sensor for parent : Make this sensor the master object for its parent device. The sensor influences the behavior of its parent device: If the sensor is in the Down status, the device is paused.

For example, it is a good idea to make a Ping sensor the master object for its parent device to pause monitoring for all other sensors on the device in case the device cannot even be pinged. Additionally, the sensor is paused if the parent group is paused by another dependency.

Dependency This setting is only visible if you enable Select a sensor above. For each user group, you can choose from the following group access rights: Inherited : Inherit the access rights settings of the parent object. No access : Users in this user group cannot see or edit the sensor. View the cache module board error code object to determine why the write cache operations have been temporarily disabled. Indicates that cache operations have been permanently disabled.

View the cache module board error code object to determine why the write cache operations have been disabled. Indicates that the flash memory component of the flash backed cache module is not attached. This status will be set when the flash memory is not attached and the Supercap is attached. This value is only used on flash backed cache modules that support removable flash memory. Indicates that the cache module board is currently degraded and operating at a failsafe speed. The controller is currently operating in Zero Memory Raid mode.

This status may be caused by virtual space limitations in certain operating systems and is only applicable to B-Series controllers. This monitors the status of each backup power source on the board. The backup power source can only recharge when the system has power applied.

Other 1 Indicates that the instrument agent does not recognize backup power status. You may need to update your software. Recharging 3 The array controller has one or more cache module backup power sources that are recharging. Failed 4 The battery pack is below the sufficient voltage level and has not recharged in 36 hours. Degraded 5 The battery is still operating, however, one of the batteries in the pack has failed to recharge properly.

NotPresent 6 A backup power source is not present on the cache module board. Some controllers do not have backup power sources.

Capacitor Failed 7 The flash backed cache module capacitor is below the sufficient voltage level and has not recharged in 10 minutes. Your Cache Module board needs to be serviced.

The physical location of this node e. If the location is unknown, the value is the zero-length string. The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree 1.